Optical Transceiver SFP+ 10.3125Gb/s 10KM 1310nm LC
กดเพื่อขยายขนาด |
|
Product Specification Sheet
OLSP311XL-CD10R
10Gb/s 1310nm Single-mode SFP+ Receiver
PRODUCT FEATURES
10Gb/s serial optical interface compliant to 802.3ae 10GBASE-LR.
PIN photo-detector
Up to 10km transmission on SMF
Duplex LC connector
Metal enclosure, for lower EMI
Electrical interface compliant to SFF-8431
Specifications for 10 Gigabit “SFP+”
Specifications compliant with SFF 8472
Single 3.3V power supply
Case operating temperature range: 0°C to 70°C
APPLICATIONS
10GBASE-LR/LW 10G Ethernet
STANDARD
Compliant with SFF-8472 SFP+ MSA.
Compliant to SFP+ SFF-8431 and SFF-8432.
Compliant to 802.3ae 10GBASE-LR.
RoHS Compliant.
FUNCTIONAL DIAGRAM
ABSOLUTE MAXIMUM RATINGS
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the module
GERERAL OPERATING CHARACTERISTICS
ELECTRICAL INPUT/OUTPUT CHARACTERISTICS
Receiver
Note 1) TD+/- are internally AC coupled with 100Ω differential termination inside the module.
Note 2) Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
Note 3) RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES.
OPTICAL CHARACTERISTICS
Receiver (0~70℃@10.3125Gb/s)
Note 1) Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations.
Note 2) 20%~80%
Note 3) Measured with a PRBS 231-1 test pattern, @6.25Gb/s, BER<10-12
SERIAL INTERFACE FOR ID AND DDM
The SFP modules implement the 2-wire serial communication protocol as defined in the SFP
MSA.
The serial ID information of the SFP modules and Digital Diagnostic Monitor parameters can be
accessed through the I2C interface at address A0h and A2h. The memory is mapped in Table 1.
Detailed ID information(A0h) is listed in Ta-ble 2. And the DDM specification(A2h) is described
in Table 3. For more details of the memory map and byte definitions, please refer to the
SFF-8472 (Rev 9.3, Aug. 2002), “Digital Diagnostic Monitoring Interface for Optical
Transceivers”.
The DDM parameters have been internally calibrated.
Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)
PIN DEFINITIONS AND FUNCTIONS
Note 1) The module ground pins shall be isolated from the module case.
Note 2) This pin is an open collector/drain output pin and shall be pulled up with
4.7K-10Kohms to Host_Vcc on the host board.
Note 3) This pin shall be pulled up with 4.7K-10Kohms to VccT in the module.
Note 4) This pin is an open collector/drain output pin and shall be pulled up with
4.7K-10Kohms to Host_Vcc on the host board. In FC designated as RX_LOS, inSONET
designated as LOS, and in Ethernet designated at Signal Detect.
TYPICAL INTERFACE CIRCUIT
Recommended power supply filter
Note: Inductors with DC resistance of less than 1Ω should be used in order to maintain the
required voltage at the SFP input pin with 3.3V supply voltage. When the recommended
supply filtering network is used, hot plugging of the SFP transceiver module will result in an
inrush current of no more than 30 mA greater than the steady state value
PACKAGE DIMENSION